Product Placement

 

 
Due to the reliable clinical data available in using The EIS System the applications are tremendous. Any healthcare facility will benefit from The EIS System.The field of bio-impedance is recognized by the Medical/Government institutions including The US FDA.
 
Indications or Intended use 
Medical system  ( Europe, Canada) or biofeeback system  for patient’s monitoring of diseases
1. Monitoring of the treatment of diseases 
2. Statistical Nutritional analysis
3. Body composition from algorithms formula (Hume and James) and predictive equations from peer reviews
The intended uses 2 and 3 should be use in healthy subjects, applicable age range from 10 to 80 years old.
The system does not make a diagnosis
The system should be use by licensed health professional.
 Identification of the treatments'monitoring and corresponding diseases

 

Diseases  Treatments
 Hypothyroidism                                                      Thyroid substitute hormone
Hypertension (High Blood pressure)  

Beta Blockers
Converting Enzyme Inhibitors

Atherosclerosis Anticoagulants
 Depression                                                              IRSS
Water retention and dehydration disorders Diuretics

Performances of the device
Measurement of the following interstitial fluid parameters:
•Intensity in µA (Ohm law)
•Resistance in §Ù (Ohm law)
•Conductivity in S.m-1 (Ohm law)
•Volume in liter ((Segal et al 1991)
Measurement of the volume of extracellular water in liter (Deurenberg et al 1994)
Estimation of the body composition according to the predictive equations from the peer reviews
•BMI  = Weight / Ht2
•TBW From Hume formula
•EWC
•Lean mass
•Fat mass= total weight-lean mass  
•Muscular mass= TWBX 0.417  
•Intracellular water = TWB- ECW
•Basal metabolic rate / 24 Hours
Harris/Benedict and Roza / Shizgal‘sformula
Men = 13,707 x Weight (kg) + 492, 3 x Height (m) - 6,673 x Age (y) + 77, 607
Women = 9,740 x Weight (kg) + 172, 9 x Height (m) - 4,737 x Age(y) + 667, 051
 
Extrapolation of interstitial fluid volume measurement and physiological and biochemical parameters according to the physiology knowledge of the interstitial fluid physiology, the Cottrell equation, the clinical tests and the cells’ activity and ionic equilibrium:
These extrapolations are not claims of performances of the system, but they can help for physiological interpretation of the results.
•interstitial Na+
•Interstitial pH 
•Tissue oxygen uptake
•Interstitial oxygenation delivery
•ATP Mitochondrial production
•Arterial Capillary Hydrostatic Pressure
•Interstitial Osmotic Pressure
•Interstitial K+ 
•interstitial Mg
•interstitial Cl-
•TSH
Identification of the human body systems in the modeling
•Neurologic system
•Cardiovascular system
•Concerning the endocrine system only the Thyroid activity
•Digestive system
•Urogenital system
•Respiratory system
 
The EIS System as tool to track your clients improvements.
 
The cornerstone of The EIS System is the ability to monitor the efficacy of  treatment modality/protocol. Over the years this has proved an invaluable tool for licensed practitioners and therapists to enable them to track their clients current state of health according to certain physiological parameters.
 
Please note LD Technology does not necessary support any specific product protocol. The EIS System is a measurement tool and as such will enable the practitioner to gauge whether their treatment protocol is effective or not. Treatments can range from chemotherapy to antibiotics to herbs to nutritional supplements to other frequency generating devices. It is the aim of The EIS System to support all current protocols by offering a valuable tool to monitor client improvement.
 
 
Undesirable side effects
 
No side effects or adverse reactions are known to date. The EIS System delivers far less electrical energy than many other common biomedical devices. Specifically, 84.5 milliJoules (mJ; or 0.0845 J) of electrical energy pass through the body, distributed across different anatomical regions, in the 110 seconds of active scanning in an EIS examination. Expressed as electrical power (electrical power is defined as Watts (W). 1 Watt = 1 Joule/s), The EIS System operates at 0.00077 W.  To put this figure in perspective, compare the 0.00077 W to a standard incandescent light bulb using 60W of electrical power. The light bulb draws nearly 78,000 times more energy than The EIS System.
 
Contraindications
 
General Contra indications
  • Dermatological lesions in contact with the electrodes or excessive perspiration
  • This device should not be used in association with or presence of defibrillators, cardiac pacemakers, patients connected to electronic life support devices, or any implanted electronic device.
  • People unable to be held upright or seated
  • Metal pins or prostheses on the level of the extremities or the joints
  • This device should not be used on pregnant women. The effects on the foetus, as well as the accuracy of readings are unknown.
  • An absence of one or more limbs.
  • The site of the system: the ground in synthetic material and a relative humidity < 30% can prevent measurement. The system is sensitive to the important electromagnetic discharges owing to the fact that it measures a very low current.
 
Supplementary contra indications for the calculation of the body composition
  • Age ( < 16 and > 80)
  • Fever
  • Drugs
  • Strong alcohol or stimulants (amphetamines) 12 hours before the examination
  • Diarrhoea
  • Intense physical activity 8 hours before the examination
  • Edema
 
Warning
 
Training and certification are required to be able to use The EIS System.
 

The use of The EIS System requires level 1 training and level 1 certification . Basic setup and initial level 1 training and level 1 certification (quiz) are available online .

Level 2 is provided by LD Technology endorsed  trainers together with LD Technology. Typically level 2 trainings are provided by experts in the field of bio-impedance with The EIS System.

 
You are required to schedule your level 2 training upon completion of level 1 training. A certificate of training will be awarded to you upon completion of level 1 basic training.
 
DISCLAIMERS
 
  • The interpretation of The EIS System requires medical knowledge of physiology and of adequate references, the subject’s clinical context and a list of variables which can modify the results. The interpretation is the responsibility of the health care professional.
  • The EIS System does not replace or endorse any existing medical examination
  • This device is not intended to be used for diagnosis.  
  • The result of The EIS System without any abnormal values does not mean that the patient is healthy; it means only that there are no interstitial fluid or extracellular volume disorders.
 
ONLY A LICENCED DOCTOR CAN DIAGNOSE A PATIENT
 